Smart 7kW rack load bank with variable air flow

Rentaload offers rental of the first 7kW variable air flow loadbank with power source converter. With 2 possible supply sources, this load bank makes it possible to test the changeover from a main supply channel to an emergency route.

With a precision of 0.5kW, the rack load bank is the most accurate on the market.

Smart 6kW rack load bank with variable air flow

Rentaload offers rental of the first 6kW variable air flow loadbank with power source converter 100% on line A, 100% on line B or 50% or line A & 50% on line B . With 2 possible supply sources, this load bank makes it possible to test the changeover from a main supply channel to an emergency route or to share the load between 2 sources.

With a precision of 1kW, the rack load bank is the most accurate on the market.

Thermal test: choice of T ° Delta variable air flow

The user interface has been completely reviewed on this load bank. The person who tests can now have information & measurements thanks to the sofware connected to the load bank (see image below). The transmitted measurements are:

  • The air inlet temperature
  • The outlet temperature
  • The Delta T °
  • The power
  • Voltage
  • The flow

Finally, for specific thermal tests, the T ° delta can be entered by the user. The load bank ventilation will vary according to the instructions.

Banc_de_charge_simulateur_serveur_rackable_connecté_delta_t_10_commissioning
Smart 7kW rack loadbank Technical Datasheet
Smart 6kW rack loadbank Technical Datasheet
smart-rack-loadbank_server emulator_test_heater_hotbox

Commissioning of your Datacenter

The connected 7kW power rack has a dual power supply and  a T ° delta equivalent to the computer servers.

Smart load Bank
recette data center banc de charge connecté location

Rack load bank accessories

The Rentalab tool allows you to control up to 200 load banks at the same time, retrieve electrical & thermal information from your room and generate test reports.

Commissioning Software

Industries we serve

Data Centers / Telecom

IST Commissioning, testing critical infrastrucure (Generators, UPS, air conditionning, etc.) ensuring that a data centre maintains its reliability

Hospitals and Healthcare Facilities

Regular testing of the emergency backup generators & UPS with Rentaload’s load banks

Utility & substations

Testing & commissioning electrical plants, microgrids & emergency back-up generators

Maritime

Testing and Commissioning Maritime power generators & habor cranes